User interface
Figure 2: TX3H pin-out and dimension
(compared to TX3A)
|
| |
| TX1H pin |
Name |
Function |
| 1, 3 |
RFgnd |
RF Ground |
| 2 |
RF out |
50W
RF output to the antenna |
| 4 |
EN
|
Pull high to enable
Transmitter |
| 5 |
Vcc |
5V regulated DC power
supply |
| 6 |
0V |
Supply Ground |
| 7 |
TXD |
DC coupled input for
5V CMOS logic. Rin = 100kW |
| NOTE: Pin
out as TX1H and standard TX3A |
|
 |
| |
|
Performance specifications
Operating temperature: -40°C to +85°C
(Figures apply at +25°C, 5.0V supply
unless otherwise stated)
|
| General |
pin |
min. |
typ. |
max. |
units |
notes |
| |
|
|
|
|
|
|
| DC supply |
|
|
|
|
|
|
| Supply
voltage |
5, 6
|
4.9
|
5
|
5.1
|
V
|
|
| TX Supply current |
5, 6
|
-
|
310
|
-
|
mA
|
|
| |
|
|
|
|
|
|
| RF |
|
|
|
|
|
|
| RF power output |
2
|
+25.5
|
+26.5
|
+27
|
dBm
|
1
|
| Spurious emissions,
<1GHz |
2
|
-
|
-
|
-54
|
dBm
|
2
|
| Spurious emissions,
>1GHz |
2
|
-
|
-
|
-40
|
dBm
|
2
|
| RF centre
frequency |
|
-
|
869.50
|
-
|
MHz
|
3
|
| Initial Frequency accuracy |
|
- 15
|
0
|
+15
|
kHz
|
2
|
| Overall Frequency accuracy |
|
- 40
|
0
|
+40
|
|
5
|
| FM deviation (peak) |
|
-
|
±27
|
-
|
kHz
|
4
|
| Antenna pin impedance |
2
|
-
|
50
|
-
|
W
|
|
| Number of channels |
|
-
|
1
|
-
|
|
|
| |
|
|
|
|
|
|
| Baseband |
|
|
|
|
|
|
| Modulation bandwidth
@ -3dB |
|
0
|
-
|
8
|
kHz
|
6
|
| Maximum raw data rate |
|
-
|
10
|
16
|
kbps
|
6
|
| TXD input level (logic
low) |
7
|
-
|
0
|
-
|
V
|
7
|
| TXD input level (logic
high) |
7
|
-
|
5.0
|
-
|
V
|
7
|
| |
|
|
|
|
|
|
| Dynamic timing |
|
|
|
|
|
|
| TX select to full RF |
|
-
|
53
|
55
|
ms
|
|
| |
|
|
|
|
|
|
|
Notes:
1. Measured into 50W resistive
load
2. Meets EN requirements at all frequencies
3. There is a <10% duty cycle restriction on 869.50 MHz
in EU member states
4. Total over full supply and temperature range
5. With 0V - 5.0V modulation input
6. 5V CMOS compatible
7. To achieve specified FM deviation |
 |
| |
|
Limitation of liability
The information furnished by Radiometrix
Ltd is believed to be accurate and reliable. Radiometrix
Ltd reserves the right to make changes or improvements in
the design, specification or manufacture of its subassembly
products without notice. Radiometrix Ltd does not assume
any liability arising from the application or use of any
product or circuit described herein, nor for any infringements
of patents or other rights of third parties which may result
from the use of its products. This data sheet neither states
nor implies warranty of any kind, including fitness for
any particular application. These radio devices may be subject
to radio interference and may not function as intended if
interference is present. We do NOT recommend their use for
life critical applications.
The Intrastat commodity code for all our modules is: 8542
6000.
R&TTE Directive
After 7 April 2001 the manufacturer can
only place finished product on the market under the provisions
of the R&TTE Directive. Equipment within the scope of
the R&TTE Directive may demonstrate compliance to the
essential requirements specified in Article 3 of the Directive,
as appropriate to the particular equipment.
Further details are available on The Office of Communications
(Ofcom) web site:
Licensing
policy manual
|
 |